Starter Generator Terminal Block Connections

June 2018

All starters and generators need a way to connect wires to the aircraft. Most units accomplish this via a terminal block. The block is very basic and is made from a non-conductive material with threaded studs to join the aircraft wiring to the generator wiring. Though basic, proper torque and wire placement is critical. These units draw and generate enormous amounts of current, and a loose wire could lead to catastrophic failure.

A loose wire will cause arcing between the generator wiring, the stud, and the aircraft wiring. If the wires are too loose, this condition may go unnoticed for a period of time, but during that time, damage is still being done. The arcing acts like a welder fusing the parts together by melting, and this causes poor performance during starting and running the generator. If left in this condition the generator life will be shortened, and failure is imminent.

You can see in the photos below the damage that occurs when a single nut is not torqued correctly, leading to arcing and melting. This unit’s positive aircraft wire terminal completely disintegrated and fell to the side, resulting in not only terminal damage but also damage to the external generator housing and surrounding aircraft frame.

20180605_09012120180605_09004020180605_09011020180411_091902

Contact

Jerry Cable Accessory Tech Rep Astra, Challenger, Citation, Embraer, Falcon, Global, Gulfstream, Hawker, King Air, Learjet, Westwind Lincoln, NE (LNK) +1 402.479.8112

Related Tech Articles

Four Benefits To Component Tracking Through myDuncan
May 2021


Webinar: The Importance of Engineering at Duncan Aviation
February 2021


Talking To The Principal About Comparing Quotes
February 2021


Don’t Delay Sending Control Rod Assemblies In For Repair/Overhaul
January 2021


Challenger 604 Aircraft Parts Inventory Addition
December 2020


View All Accessories Airframe Maintenance Tech Articles