Starter Generator Terminal Block Connections

June 2018

All starters and generators need a way to connect wires to the aircraft. Most units accomplish this via a terminal block. The block is very basic and is made from a non-conductive material with threaded studs to join the aircraft wiring to the generator wiring. Though basic, proper torque and wire placement is critical. These units draw and generate enormous amounts of current, and a loose wire could lead to catastrophic failure.

A loose wire will cause arcing between the generator wiring, the stud, and the aircraft wiring. If the wires are too loose, this condition may go unnoticed for a period of time, but during that time, damage is still being done. The arcing acts like a welder fusing the parts together by melting, and this causes poor performance during starting and running the generator. If left in this condition the generator life will be shortened, and failure is imminent.

You can see in the photos below the damage that occurs when a single nut is not torqued correctly, leading to arcing and melting. This unit’s positive aircraft wire terminal completely disintegrated and fell to the side, resulting in not only terminal damage but also damage to the external generator housing and surrounding aircraft frame.

20180605_09012120180605_09004020180605_09011020180411_091902

Contact

Jerry Cable Accessory Tech Rep Astra, Challenger, Citation, Embraer, Falcon, Global, Gulfstream, Hawker, King Air, Learjet, Westwind Lincoln, NE (LNK) +1 402.479.8112

Related Tech Articles

Have You Replaced Your Handheld Halon Type 1211 Portable Fire Extinguishers?
June 2023


Falcon Aircraft Tow Gear In Service
April 2023


Bombardier Learjet Aircraft: Piston Care On MLG Actuators
January 2023


Falcon 7X: Opening and Closing the Cowl—It’s a two-man job!
October 2022


MSP Avionics and Mechanical Components (HAPP) Flight Hour Overage Charges
October 2022


View All Accessories Airframe Maintenance Tech Articles